Description:
Displays the manufacturing information.
Form:
MANUFACTURE|MFG|MF
Argument List:
none
Response:
MANUFACTURE RESPONSE
Verbose- "OK\r\n" to acknowledge receipt of command, followed by
"Product Name= \r\n", followed by
"Part Name= \r\n", followed by
"Date= \r\n", followed by
"Serial Number= \r\n" or
"ERROR- [Description]\r\n" if error, ending command
Terse- "0\r\n" to acknowledge receipt of command, or
"[Product Name] [Part Name] [Date] [Serial Number]\r\n", or
"[NON-ZERO NUMERIC VALUE]\r\n" if error, ending command
"\r\n" concludes modify responses (empty line)
Examples:
Verbose command to retrieve current setting:
MANUFACTURE <enter>
Response is: OK\r\n
Product Name=edje-4111\r\n
Part Name=3321\r\n
Date= 1999-05-24\r\n
Serial Number=00000103E3\r\n
MicroMonitor Version=\r\n
CPLD Version=\r\n
"Optional Parameters"
hde Params
Model=KINGSTON
FwRev=2006
SerialNo=KINGSTON C
Terse command to retrieve current setting:
MF <enter>
Response is: 0\r\n
edje-4111 PART 1999 12 31 00000103E3 UMONVER CPLDVER
Soloist2 PC3321 01999 005 024 0000744700\r\n
Notes: